A lot of people assume a radon system works by pulling the gas out of their living space, like a kitchen exhaust fan clearing smoke. It doesn’t. A sub-slab depressurization system never touches the air you breathe. It works entirely underneath the concrete, changing the pressure in the soil so that radon has no reason to come up through the floor in the first place. Once you understand that distinction, the rest of the machine makes sense. Here is how the components actually move soil gas from beneath your basement to a point well above the roof.

Inside the Mechanics of a Sub-Slab Depressurization System

The Suction Point Beneath the Slab

Everything starts with a hole cored through the concrete slab, usually three to five inches across. Below that slab is a layer of gravel, crushed stone, or disturbed soil, and that layer is where the system does its work. An installer scoops out a cavity under the hole, sometimes removing a bucket or two of material to create a small void. This void becomes the collection point. Instead of trying to draw gas from one tiny spot, the cavity lets suction spread laterally through the permeable layer, reaching far beyond the single penetration.

A pipe is sealed into that cored hole with hydraulic cement or an airtight rubber boot. From this point on, the system is a closed loop that begins in the ground and ends in open air. The quality of that seal matters more than most homeowners realize: a loose or cracked collar lets the fan pull basement air instead of soil gas, wasting suction where it does nothing.

How the Fan Creates a Pressure Difference

The fan is the engine, and it is deliberately modest. A typical radon fan is a small inline centrifugal unit that draws somewhere around 30 to 90 watts, roughly the appetite of a light bulb. It does not need brute force because it is not moving a large volume of air. Its job is to create a slight negative pressure under the slab, measured in fractions of an inch of water column.

That tiny pressure difference is the whole trick. Soil gas naturally drifts toward lower pressure. The ground beneath an unmitigated home is often at a slightly higher pressure than the basement, which is why radon seeps up through cracks and the slab perimeter. By making the sub-slab zone the lowest-pressure point in the system, the fan reverses the pull. Radon that would have risen into the basement is instead drawn sideways into the cavity and up the pipe. The fan runs continuously, year-round, because that pressure field has to be maintained without interruption.

The Path Air Takes Through the Vent Pipe

From the suction point, PVC pipe carries the gas upward. Most installations use three- or four-inch schedule 40 pipe, routed either up through the interior of the house or along an exterior wall. The fan sits somewhere along this run, and by code it is almost always placed outside the living space — in an unconditioned attic, a garage, or outdoors on the exterior. That placement is intentional: if the pipe ever develops a leak on the pressurized side downstream of the fan, you want that leak outside your breathing space, not inside it.

The pipe continues to a discharge point above the roofline, typically at least a foot above the roof surface and set back from windows, doors, and attic vents so the gas disperses harmlessly into outdoor air. Firms that handle Radon Mitigation York PA pay close attention to this routing, pitching horizontal runs so condensation drains back down toward the soil rather than pooling in a low spot where it could restrict airflow or freeze. A well-planned pipe path is quiet, out of the way, and leaves almost nothing visible inside the finished part of the home.

Reading the Manometer and Confirming the System Works

Mounted on the vent pipe is a simple U-shaped tube partially filled with colored liquid, called a manometer. When the fan is off, the liquid sits level on both sides. When the system is running correctly, the suction pulls one column higher than the other, and that offset is your at-a-glance proof that pressure is being maintained under the slab.

This gauge is the one part of the system a homeowner is meant to watch. Make a habit of glancing at it: if the two columns ever return to level, the fan has likely failed or the pipe is blocked, and radon can start climbing again. Pair that quick check with a fresh radon test every couple of years and after any major foundation or slab work, and the system will keep doing its quiet job underground for years to come.